Econex QA Quantometers – Turbine Gas Meters

Econex QA quantometers: non-fiscal turbine gas meters QA25/GI, QA40/GFI, QA65/ZI and QA160/ZI, from 1″ to DN 80 and 2.5 to 250 m³/h, to measure the gas consumption of kilns and burners. Authorised Econex distributor.

Description

Econex QA quantometers

Non-fiscal turbine gas meters to measure the gas consumption of kilns, dryers and burners: QA25/GI, QA40/GFI, QA65/ZI and QA160/ZI, from 1″ to DN 80. From an authorised Econex distributor. Send us the part code for a quote.

Send us the part codeWhatsApp

Econex QA quantometers: turbine gas meters for industrial use

Econex QA quantometers are compact turbine gas meters for non-fiscal applications. The gas flowing through the meter turns a turbine wheel: the number of revolutions is proportional to the volume of gas, which is recorded by a mechanical 7-digit index (QA) or by an electronic index (QAe). Self-lubricating bearings mean no regular maintenance.

On ceramic kilns, dryers, boilers and furnaces the QA measures the gas used by each line or burner, so you can monitor consumption, allocate costs inside the plant and calculate production costs. The QA and QAe quantometers are made by Elster and supplied as part of the Econex gas measurement range. Atlas Trading is an authorised Econex distributor.

Why buy Econex from Atlas Trading

  • Competitive prices on the whole Econex range
  • Components from an Italian manufacturer active since 1979
  • Fast access to Econex’s large stock
  • Actuators, solenoid valves, pressure switches, flame control, gas meters and gas trains
  • Send us the part code: we identify the part for you
  • We reply in English, Spanish, French and Portuguese – worldwide shipping

Request a quote

On this page: Models · Technical data · Pulse outputs · Installation and dimensions · How to order · FAQ

QA models we supply

ModelConnectionFlow rate (Qmin–Qmax)
QA25/GIDN 25, 1″ internal thread (DIN ISO 228)2.5–40 m³/h
QA40/GFIDN 40, 1½″ internal thread (DIN ISO 228)5–65 m³/h
QA65/ZIDN 50, wafer between PN 10/16 flanges6–100 m³/h
QA160/ZIDN 80, wafer between PN 10/16 flanges13–250 m³/h

The QA range goes from QA10 to QA1000: DN 25 to DN 150, 1.6 to 1,600 m³/h. Other sizes and the electronic QAe version are available on request.

Technical data

QA / QAeData
Measuring principleTurbine wheel; mechanical index (QA) or electronic index (QAe)
Measuring rangeUp to 1:20; overload up to 160% of the maximum flow rate
AccuracyWithin 1% from 0.2 Qmax to Qmax; precision independent of gas density, pressure and temperature within a wide range
GasesNatural gas, methane, air, nitrogen and other non-corrosive gases
Maximum pressureCombustible gases: 4 bar (GI, GFI), 20 bar (ZI; QAe 4 bar). Air and inert gases: 16 bar (GI, GFI)
BodyAluminium
TemperatureQA −10 to +60 °C · QAe 0 to +50 °C
Protection classIP52 (QA) · IP44 (QAe)
IndexQA: mechanical, 7 digits. QAe: LCD with total volume, current flow rate, daily values and back-flow volume
ApprovalsDVGW, ATEX, PED
MaintenanceNone required (self-lubricating bearings)

Pulse outputs and interfaces

ModelLF reed contact E1MF inductive output E200
QA25/GI10 pulses/m³500 pulses/m³
QA40/GFI1 pulse/m³250 pulses/m³
QA65/ZI1 pulse/m³250 pulses/m³
QA160/ZI1 pulse/m³187.5 pulses/m³

Reed contact E1: max 24 V, 50 mA, 0.25 W. Output E200: inductive slot sensor to DIN EN 50227 (Namur), 8 V dc. Both with 3-pin connector to DIN 41524. The QAe also has an optical interface (EN 1434, ZVEI) and an M-Bus interface.

Installation and dimensions

The QA can be mounted in any position, horizontal or vertical; the flow direction is shown by an arrow on the body. The GI and GFI versions are screwed into the pipe, the ZI versions are clamped between two flanges PN 10/16 (EN 1092-1 or ANSI 150).

ModelHeight A (mm)Length C (mm)G (mm)Weight (kg)
QA25/GI1592401151
QA40/GFI2021901502.2
QA65/ZI202601501.4
QA160/ZI2251201505.3

QAe: A and G are 25 mm higher.

How to order

  • The model – for example QA65/ZI – or a photo of the label
  • QA (mechanical) or QAe (electronic) index
  • For a new installation: gas, pressure, flow rate and pipe size
  • The pulse output you need and the quantity

Technical documentation

Econex QA / QAe quantometers datasheet (PDF): models QA10 to QA1000, flow ranges, dimensions, pulse outputs and installation.

Frequently asked questions

What is a quantometer?

A non-fiscal turbine gas meter: it measures the volume of gas used by a kiln, a dryer, a burner or a production line, to monitor consumption and calculate production costs. It is not used for billing by the gas supplier.

Which QA size do I need?

It depends on the flow rate and the pipe: QA25/GI 2.5–40 m³/h (1″ thread), QA40/GFI 5–65 m³/h (1½″ thread), QA65/ZI 6–100 m³/h (DN 50) and QA160/ZI 13–250 m³/h (DN 80). Other sizes go from 1.6 to 1,600 m³/h.

What is the difference between QA and QAe?

The QA has a mechanical 7-digit index. The QAe has an electronic index with LCD display of total volume, current flow rate, daily values and back-flow volume, plus optical and M-Bus interfaces.

Which gases can the QA measure?

Natural gas, methane, air, nitrogen and other non-corrosive gases.

What is the maximum pressure?

With combustible gases 4 bar for the threaded GI and GFI versions and 20 bar for the wafer ZI versions (QAe: 4 bar). With air and inert gases 16 bar for the GI and GFI versions.

Can the QA send pulses to a PLC or a controller?

Yes. The QA has a low-frequency reed contact E1 and a medium-frequency inductive output E200 (Namur, EN 50227), for example 1 pulse/m³ and 187.5 pulses/m³ on the QA160.

Are you an Econex distributor?

Yes. Atlas Trading is an authorised Econex distributor: we supply Econex components, QA quantometers included, with access to the manufacturer’s stock.

Do you ship worldwide?

Yes. We supply customers worldwide and reply in English, Spanish, French and Portuguese.


See the full Econex range or request a quote.

Request a quote

    Send us the part code, the machine model or a photo of the nameplate. We reply in English, Spanish, French and Portuguese.